[PATCH v3 1/3] thermal: cpufreq_cooling: Update also offline CPUs per-cpu thermal_pressure

From
Lukasz Luba <lukasz.luba@arm.com>
Date
2021-06-10 15:03:43
Also in
lkml
Reply to
Lukasz Luba, 2021-06-10
The thermal pressure signal gives information to the scheduler about
reduced CPU capacity due to thermal. It is based on a value stored in a
per-cpu 'thermal_pressure' variable. The online CPUs will get the new
value there, while the offline won't. Unfortunately, when the CPU is back
online, the value read from per-cpu variable might be wrong (stale data).
This might affect the scheduler decisions, since it sees the CPU capacity
differently than what is actually available.

Fix it by making sure that all online+offline CPUs would get the proper
value in their per-cpu variable when thermal framework sets capping.

Fixes: f12e4f66ab6a3 ("thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping")
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
---
 drivers/thermal/cpufreq_cooling.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c
index eeb4e4b76c0b..43b1ae8a7789 100644
--- a/drivers/thermal/cpufreq_cooling.c
+++ b/drivers/thermal/cpufreq_cooling.c
@@ -478,7 +478,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
 	ret = freq_qos_update_request(&cpufreq_cdev->qos_req, frequency);
 	if (ret >= 0) {
 		cpufreq_cdev->cpufreq_state = state;
-		cpus = cpufreq_cdev->policy->cpus;
+		cpus = cpufreq_cdev->policy->related_cpus;
 		max_capacity = arch_scale_cpu_capacity(cpumask_first(cpus));
 		capacity = frequency * max_capacity;
 		capacity /= cpufreq_cdev->policy->cpuinfo.max_freq;
-- 
2.17.1
Thread (10 messages) 10 messages, 3 authors, last reply 2021-06-14
Keyboard shortcuts
hback out one level
jnext message in thread / next series-diff position
kprevious message in thread / previous series-diff position
ldrill in
Escclose help / fold thread tree
?toggle this help