Re: [PATCH 08/10] input: iqs5xx: Allow more time for ATI to complete

From
Dmitry Torokhov <dmitry.torokhov@gmail.com>
Date
2021-01-25 04:42:33
Reply to
Jeff LaBundy, 2021-01-18
On Mon, Jan 18, 2021 at 02:43:44PM -0600, Jeff LaBundy wrote:
After the device is initialized, it runs ATI (calibration) during
which it cannot readily respond to I2C communication. To keep the
open and close callbacks from writing to the device too soon, the
driver waits 100 ms before returning from probe.

The vendor reports that ATI may actually take up to 250 ms to run
(including margin), so increase the delay accordingly. Update the
comments to clarify the reason for the delay as well.

Signed-off-by: Jeff LaBundy <redacted>
Applied, thank you.

-- 
Dmitry
Thread (23 messages) 23 messages, 2 authors, 2021-01-26