Thread (63 messages) 63 messages, 11 authors, 2012-08-07

Re: [RFC][PATCH v3 1/3] runtime interpreted power sequences

From: Thierry Reding <hidden>
Date: 2012-08-01 07:41:27
Also in: linux-devicetree, linux-tegra, lkml

On Tue, Jul 31, 2012 at 04:39:41PM +0100, Mark Brown wrote:
On Tue, Jul 31, 2012 at 04:32:35PM +0200, Thierry Reding wrote:
quoted
On Tue, Jul 31, 2012 at 03:26:07PM +0100, Mark Brown wrote:
quoted
quoted
This is framework code - it doesn't have much option.  Disabling HOTPLUG
is totally reasonable on space constrained systems, there's no reason
for the code to break things for people.
quoted
Still if you use this code and disable HOTPLUG, then you shouldn't be
using modules either. I mean there is no way you can write a driver that
Of course.
quoted
can gracefully handle its platform data being discarded.
Sure there is - take a copy of the platform data in probe().
Yes, but that will only work for built-in drivers. If you unload the
module and that causes the platform data to be discarded, reloading
won't work.

Thierry