Thread (23 messages) 23 messages, 5 authors, 2026-08-19

Re: [PATCH v4 6/6] iio: dac: ad5504: support scale via output-range-microvolt property

flat view

From: Andy Shevchenko <hidden>
Date: 2026-08-18 08:33:08
Also in: linux-iio, lkml

On Tue, Aug 18, 2026 at 04:23:47AM -0400, Taha Ed-Dafili wrote:
On Mon, Aug 18, 2026 at 06:30:00AM +0300, Andy Shevchenko wrote:
...
quoted
So, the change from 1000 to MILLI is in the line that is changed
again in this patch. So, no need to change it earlier. And again, it
should be (MICRO / MILLI).
I started the code with a bare / 1000, then replaced it with MILLI
thinking it was the more readable form. I wasn't aware of the
(MICRO / MILLI) idiom for expressing unit conversions explicitly.
Will fix in v5 and drop the intermediate change from patch 5.
Since you want to get a millivolts from microvolts the 1000 is semantically
(MICRO / MILLI).

-- 
With Best Regards,
Andy Shevchenko