Thread (39 messages) 39 messages, 7 authors, 2023-10-12

Re: [PATCH v1 02/10] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

From: Dmitry Baryshkov <hidden>
Date: 2023-09-07 16:18:54
Also in: linux-arm-msm, linux-clk, linux-pm, lkml

On Thu, 7 Sept 2023 at 08:22, Varadarajan Narayanan
[off-list ref] wrote:
The set rate and determine rate operations are different between
Stromer and Stromer Plus PLLs. Hence, use stromer plus ops for
ipq_pll_stromer_plus.

Signed-off-by: Kathiravan T <redacted>
Signed-off-by: Varadarajan Narayanan <redacted>
Fixes tag?
quoted hunk ↗ jump to hunk
---
 drivers/clk/qcom/apss-ipq-pll.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c
index e170331..18c4ffe 100644
--- a/drivers/clk/qcom/apss-ipq-pll.c
+++ b/drivers/clk/qcom/apss-ipq-pll.c
@@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = {
                                .fw_name = "xo",
                        },
                        .num_parents = 1,
-                       .ops = &clk_alpha_pll_stromer_ops,
+                       .ops = &clk_alpha_pll_stromer_plus_ops,
                },
        },
 };
--
2.7.4

-- 