Thread (23 messages) flat view 23 messages, 3 authors, 2021-08-02

Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho properties

From: Guenter Roeck <linux@roeck-us.net>
Date: 2021-07-21 15:03:07
Also in: linux-hwmon

On Mon, Jul 19, 2021 at 07:46:41AM +0000, Sa, Nuno wrote:
quoted
-----Original Message-----
From: Guenter Roeck <redacted> On Behalf Of Guenter
Roeck
Sent: Friday, July 16, 2021 5:04 PM
To: Sa, Nuno <Nuno.Sa@analog.com>
Cc: Rob Herring <robh@kernel.org>; linux-hwmon@vger.kernel.org;
devicetree@vger.kernel.org; Jean Delvare [off-list ref]
Subject: Re: [RFC PATCH 3/6] dt-bindings: axi-fan-control: add tacho
properties

[External]

On 7/16/21 12:44 AM, Sa, Nuno wrote:
[ ... ]
quoted
quoted
Are you sure you can ever get this stable ? Each fan has its own
properties
and tolerances. If you replace a fan in a given system, you might get
different RPM numbers. The RPM will differ widely from system to
system
and from fan to fan. Anything that assumes a specific RPM in
devicetree
data seems to be quite vulnerable to failures. I have experienced
that
quoted
quoted
recently with a different chip which also tries to correlate RPM and
PWM
and fails quite miserably.

In my experience, anything other than minimum fan speed is really
a
quoted
quoted
recipe
for instability and sporadic false failures. Even setting a minimum
fan
quoted
quoted
speed
is tricky because it depends a lot on the fan.
I see what you mean. So, I had to go through this process when
testing
quoted
this changes because the fan I'm using is different from the default
one
quoted
used to develop and stablish the default values in the IP core. The
core

Exactly my point.
quoted
provides you with a register which contains the tacho measurements
in
quoted
clock cycles. You can read that for all the PWM points of interest
(with devmem2 for example) and make your own "calibration". I
assume
quoted
that people have to go through this process before putting some
values
quoted
in the devicetree. I'm aware this is not the neatest process but I
guess it's
quoted
acceptable...
Do you really expect everyone using a system with this chip to go
through
this process and update its devicetree configuration, and then repeat it
whenever a fan is changed ? Given how dynamic this is, I really wonder
if that information should be in devicetree in the first place.
My naive assumption was that we would only do this work at evaluation
time. After that and after we settled with a fan for some system, I expected
that changing to a different fan is not that likely. From your inputs, I guess
this is not really the case which makes this process more cumbersome (as it
also implies recompiling the devicetree for your system).

However, even if we export these as runtime parameters, services/daemons
will also have an hard time doing this "calibration" in a dynamic way. The reason
is because the way the controller works is that it only accepts a new PWM
request if it is an higher value than whatever the HW has at that moment. Thus,
going through the calibration points might be very cumbersome. I can see some
ways of handling this though but not very neat...

Since this is a FPGA core, we might have some flexibility here. Something that
came to my mind would be to have a calibration mode in the HW that would
allow us to freely control the PWM values. In that way we could go freely over
the calibration points. I guess, for safety reasons, this calibration mode would
expire after some reasonable time (that give us enough time for doing the whole
thing). The best place for doing the calibration, I guess it would be directly in the
driver since we do receive the interrupts about new tacho measurements making
things easier to sync and handle. However, given the time that takes for a new
PWM to settle + new tacho measurements, it would not be very acceptable to do this 
during probe which is definitely also not ideal (we could defer this to a worker/timer).

I'm not sure if the above makes much sense to you and it also depends on the HW
guys being on board with this mechanism.
I don't really know what to say or recommend here. Personally I think any
attempt to tie PWM values to RPM are doomed to fail. Here are a couple of
examples:

Take your test system and move the fan to a restricted place (eg close to a
wall). You'll see the fan RPM change, potentially significantly. Put it into
some place with airflow towards or away from the system (eg blow air into
the system from another place, which may happen if the system is installed
in a lab), and again you'll see fan speed changes. Open the chassis, and
the fan speed will change. I have seen fan speeds vary by up to 50% when
changing airflow.

That doesn't even take into account that replacing a fan even with a similar
model (eg after a fan failed) will likely result in potentially significant
rpm changes.

Ultimately, anything that does more than determine if a fan is still running
is potentially unstable.

Having said all that, it is really your call to decide how you want to detect
fan failures. 

Thanks,
Guenter
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help