Re: [PATCH 03/10] arm64: dts: broadcom: Fix SP805 clock-names

From
Florian Fainelli <f.fainelli@gmail.com>
Date
2020-08-31 03:57:20
Also in
linux-watchdog, lkml
Reply to
Andre Przywara, 2020-08-28
On Fri, 28 Aug 2020 14:05:55 +0100, Andre Przywara [off-list ref] wrote:
The SP805 binding sets the name for the actual watchdog clock to
"wdog_clk" (with an underscore).

Change the name in the DTs for Broadcom platforms to match that. The
Linux and U-Boot driver use the *first* clock for this purpose anyway,
so it does not break anything.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
---
Applied to devicetree-arm64/next, thanks!
--
Florian