Re: [PATCH 08/10] ARM: dts: Cygnus: Fix SP805 clocks

From
Florian Fainelli <f.fainelli@gmail.com>
Date
2020-08-31 03:55:19
Also in
linux-watchdog, lkml
Reply to
Andre Przywara, 2020-08-28
On Fri, 28 Aug 2020 14:06:00 +0100, Andre Przywara [off-list ref] wrote:
The SP805 DT binding requires two clocks to be specified, but the
Broadcom Cygnus DT currently only specifies one clock.

In practice, Linux would pick a clock named "apb_pclk" for the bus
clock, and the Linux and U-Boot SP805 driver would use the first clock
to derive the actual watchdog counter frequency.

Since currently both are the very same clock, we can just double the
clock reference, and add the correct clock-names, to match the binding.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
---
Applied to qspi-fixes, thanks!
--
Florian