Thread (37 messages) 37 messages, 7 authors, 2020-06-03

[PATCHv1 14/19] power: supply: sbs-battery: fix idle battery status

From: Sebastian Reichel <hidden>
Date: 2020-05-13 18:57:08
Also in: linux-pm, lkml
Subsystem: power supply class/subsystem and drivers, the rest · Maintainers: Sebastian Reichel, Linus Torvalds

A battery, that is neither charged, nor discharged is not
always Full. If the charger is disabled for other reasons
it might simply be idle and should be marked accordingly.

Signed-off-by: Sebastian Reichel <redacted>
---
 drivers/power/supply/sbs-battery.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/drivers/power/supply/sbs-battery.c b/drivers/power/supply/sbs-battery.c
index 2a2b926ad75c..e3c685b2c247 100644
--- a/drivers/power/supply/sbs-battery.c
+++ b/drivers/power/supply/sbs-battery.c
@@ -354,9 +354,9 @@ static int sbs_status_correct(struct i2c_client *client, int *intval)
 
 	ret = (s16)ret;
 
-	/* Not drawing current means full (cannot be not charging) */
-	if (ret == 0)
-		*intval = POWER_SUPPLY_STATUS_FULL;
+	/* Not drawing current -> not charging (i.e. idle) */
+	if (*intval != POWER_SUPPLY_STATUS_FULL && ret == 0)
+		*intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
 
 	if (*intval == POWER_SUPPLY_STATUS_FULL) {
 		/* Drawing or providing current when full */
-- 
2.26.2