Re: [PATCH 1/8] dt-bindings: mmc: Add DQS trim value to Tegra SDHCI
From: Thierry Reding <hidden>
Date: 2018-08-09 14:09:55
Also in:
linux-mmc, linux-tegra, lkml
On Thu, Aug 09, 2018 at 05:06:04PM +0300, Aapo Vienamo wrote:
On Thu, 9 Aug 2018 15:46:48 +0200 Thierry Reding [off-list ref] wrote:quoted
On Thu, Aug 09, 2018 at 02:45:15PM +0300, Aapo Vienamo wrote:quoted
On Thu, 9 Aug 2018 13:36:09 +0200 Thierry Reding [off-list ref] wrote:quoted
On Tue, Aug 07, 2018 at 04:59:57PM +0300, Aapo Vienamo wrote:quoted
Document HS400 DQS trim value device tree property. Signed-off-by: Aapo Vienamo <redacted> --- Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt | 3 +++ 1 file changed, 3 insertions(+)diff --git a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt index 3c7960a..7d294f3 100644 --- a/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt +++ b/Documentation/devicetree/bindings/mmc/nvidia,tegra20-sdhci.txt@@ -72,6 +72,7 @@ Optional properties for Tegra210 and Tegra186: trimmer value for non-tunable modes. - nvidia,default-trim : Specify the default outbound clock trimmer value. +- nvidia,dqs-trim : Specify DQS trim value for HS400 timing Notes on the pad calibration pull up and pulldown offset values: - The property values are drive codes which are programmed into the@@ -88,6 +89,8 @@ Optional properties for Tegra210 and Tegra186: - The values are programmed to the Vendor Clock Control Register. Please refer to the reference manual of the SoC for correct values. + - The DQS trim values are only used on controllers which support + HS400 timing.One of these additions says "DQS trim values", the other says "DQS trim value". It is unclear from the above how many values there are. I think this should be more explicit. Also, I don't see why the note about which controllers the DQS trim value(s) applies to is in a separate paragraph. Couldn't it be moved to the property description?It's a single value. The plural form is a mistake.quoted
Also, I think the bindings should specify which generations of Tegra do support HS400. Where else are people supposed to find that information?This property is under the "Optional properties for Tegra210 and Tegra186" section and it only applies for the said generations.What's the point of specifying that they are only used on controllers which support HS400? Are you saying that only a subset of the SDHCI controllers on Tegra210 and Tegra186 support HS400?Yes, on Tegra210 and Tegra186 only SDMMC4 supports HS400.
Good. I think that'd be good to have as part of the DT bindings documentation. Thierry
Attachments
- signature.asc [application/pgp-signature] 833 bytes