On Thu, May 24, 2018 at 02:25:34PM +0100, Robin Murphy wrote:
On 23/05/18 19:10, Guenter Roeck wrote:
quoted
On Wed, May 23, 2018 at 11:57:25AM +0100, Robin Murphy wrote:
quoted
On 22/05/18 19:47, Ray Jui wrote:
quoted
Update the SP805 binding document to add optional 'timeout-sec'
devicetree property
Signed-off-by: Ray Jui <redacted>
Reviewed-by: Scott Branden <scott.branden@broadcom.com>
---
Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
1 file changed, 2 insertions(+)
diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
index edc4f0e..f898a86 100644
--- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
+++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
@@ -19,6 +19,8 @@ Required properties:
Optional properties:
- interrupts : Should specify WDT interrupt number.
+- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
+ default timeout is 30 seconds
According to the SP805 TRM, the default interval is dependent on the rate of
WDOGCLK, but would typically be a lot longer than that :/
Depends on the definition of "default". In the context of watchdog drivers,
it is (or should be) a driver default, not a chip default.
DT describes hardware, not driver behaviour.
In this case it describes expected system behavior. Most definitely
it does not describe some hardware default.
Please note that I do not engage in discussions I consider bike-shedding.
This is one of those. Dropping out.
Guenter