On 10/12/14 11:02, Jacek Anaszewski wrote:
quoted
quoted
quoted
+Optional properties:
quoted
quoted
quoted
+- maxim,fleds : Array of current outputs in order: fled1, fled2.
s/current outputs/LED current regulator outputs used/ ?
quoted
quoted
quoted
quoted
quoted
quoted
+ Note: both current outputs can be connected to a single led
s/led/LED ? And there seem to be other similar occurrences that would
need to be put in upper case.
quoted
quoted
quoted
quoted
quoted
quoted
+ Possible values:
+ MAX77693_LED_FLED_UNUSED - the output is left disconnected,
+ MAX77693_LED_FLED_USED - a diode is connected to the output.
As noted below, I would simply use 0/1 for these.
quoted
quoted
quoted
quoted
As you have a LED sub-nodes for each LED already, isn't this redundant?
Well, it seems so :)
I agreed here recklessly. This property allows to describe the
situation when one LED is connected to both outputs. Single sub-node
can describe two type of designs: one LED connected to a single
output or one LED connected to both outputs. Therefore additional
property is needed to assess what is the actual case.
How about renaming "maxim,fleds" to "maxim,active-outputs" ?
And simply using 0 and 1 to indicate if one is used or not, rather
than defining macros for these true/false values ?
--
Regards,
Sylwester