Hi Neil, On 20/10/14 09:46, Neil Zhang wrote:
quoted
-----Original Message----- From: Will Deacon [mailto:will.deacon-5wv7dgnIgG8@public.gmane.org] Sent: 2014年7月4日 1:57 To: Neil Zhang Cc: Sudeep Holla; 'linux-lFZ/pmaqli7XmaaqVzeoHQ@public.gmane.org'; 'linux-arm- kernel-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r@public.gmane.org'; 'linux-kernel-u79uwXL29TY76Z2rM5mHXA@public.gmane.org'; 'devicetree-u79uwXL29TY76Z2rM5mHXA@public.gmane.org' Subject: Re: [PATCH v4] ARM: perf: save/restore pmu registers in pm notifier On Mon, Jun 30, 2014 at 11:39:15AM +0100, Neil Zhang wrote:quoted
quoted
quoted
quoted
I will prepare another patch to add DT description under PMU since there is no generic power domain support for pm notifier if no other concerns. We can change the manner if there is generic power domain support for pm notifier later. Thanks.No, please don't add any DT bindings for power domains specific to PMU node. We can't change the DT bindings once added. As I pointed out the DT bindings for generic power domains are under discussion. See if you can reuse it, if not help in extending it so that it can be used.Sorry for reply later. As I said before the under discussed generic power domain is not suitable for CPU peripherals since they are all known belong to CPU or cluster power domain. If we want to follow the way they are discussion, we need to register core and cluster power provider, and need vfp/gic/pmu etc to require them. Is it really suitable?Do you have any comments? If no, I would like to put it under PMU node.Sudeep is a better person to comment than me, but I'd still rather this was handled more generically as opposed to a PMU-specific hack. I don't see a problem including GIC and VFP here, but only when we actually need to save/restore them (i.e. what the hardware guys went crazy with the power domains).Long time no follow up for this loop. Sorry that I will pick it again.
Yes, the generic PD got added in v3.18-rc1, it's better to check if we can reuse it. I will also have a look at that and think about how we can use it.
Will, I prefer to check always-on field under PMU node to check whether we need Save/restore them.
But how do you handle it for different idle states. e.g. if CPU is in retention, PMU's *might be* retained. Also I don't think PMUs will be placed in "always-on" power domain like timers. So using "always-on" sounds incorrect to me. Regards, Sudeep -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org More majordomo info at http://vger.kernel.org/majordomo-info.html