Thread (13 messages) 13 messages, 5 authors, 2014-10-21

Re: [PATCH v4] ARM: perf: save/restore pmu registers in pm notifier

flat view

From: Will Deacon <hidden>
Date: 2014-07-03 17:57:31
Also in: linux-arm-kernel, lkml

On Mon, Jun 30, 2014 at 11:39:15AM +0100, Neil Zhang wrote:
quoted
quoted
quoted
I will prepare another patch to add DT description under PMU since
there is no generic power domain support for pm notifier if no other
concerns.
quoted
We can change the manner if there is generic power domain support
for
pm notifier later.
quoted
Thanks.
No, please don't add any DT bindings for power domains specific to PMU
node.
We can't change the DT bindings once added.

As I pointed out the DT bindings for generic power domains are under
discussion.
See if you can reuse it, if not help in extending it so that it can be used.
Sorry for reply later.
As I said before the under discussed generic power domain is not suitable for
CPU peripherals since they are all known belong to CPU or cluster power
domain.
If we want to follow the way they are discussion, we need to register core
and cluster power provider, and need vfp/gic/pmu etc to require them.
Is it really suitable?
Do you have any comments?
If no, I would like to put it under PMU node.
Sudeep is a better person to comment than me, but I'd still rather this was
handled more generically as opposed to a PMU-specific hack. I don't see a
problem including GIC and VFP here, but only when we actually need to
save/restore them (i.e. what the hardware guys went crazy with the power
domains).

Will
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help