Re: [PATCH v4] ARM: perf: save/restore pmu registers in pm notifier
flat view
From: Will Deacon <hidden>
Date: 2014-07-03 17:57:31
Also in:
linux-arm-kernel, lkml
On Mon, Jun 30, 2014 at 11:39:15AM +0100, Neil Zhang wrote:
quoted
quoted
quoted
I will prepare another patch to add DT description under PMU since there is no generic power domain support for pm notifier if no otherconcerns.quoted
We can change the manner if there is generic power domain support forpm notifier later.quoted
Thanks.No, please don't add any DT bindings for power domains specific to PMU node. We can't change the DT bindings once added. As I pointed out the DT bindings for generic power domains are under discussion. See if you can reuse it, if not help in extending it so that it can be used.Sorry for reply later. As I said before the under discussed generic power domain is not suitable for CPU peripherals since they are all known belong to CPU or cluster power domain. If we want to follow the way they are discussion, we need to register core and cluster power provider, and need vfp/gic/pmu etc to require them. Is it really suitable?Do you have any comments? If no, I would like to put it under PMU node.
Sudeep is a better person to comment than me, but I'd still rather this was handled more generically as opposed to a PMU-specific hack. I don't see a problem including GIC and VFP here, but only when we actually need to save/restore them (i.e. what the hardware guys went crazy with the power domains). Will -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org More majordomo info at http://vger.kernel.org/majordomo-info.html