Thread (8 messages) flat view 8 messages, 2 authors, 2012-03-20

Re: [PATCH] mgmt-api: add read Tx power level command

From: Arik Nemtsov <hidden>
Date: 2012-03-12 18:07:08

On Mon, Mar 12, 2012 at 19:29, Marcel Holtmann [off-list ref] wrote:
Hi Arik,
quoted
quoted
quoted
This command reads the Tx power level for a given connected device
---
=A0doc/mgmt-api.txt | =A0 28 ++++++++++++++++++++++++++++
=A01 files changed, 28 insertions(+), 0 deletions(-)
diff --git a/doc/mgmt-api.txt b/doc/mgmt-api.txt
index 4ede43d..8dae2b4 100644
--- a/doc/mgmt-api.txt
+++ b/doc/mgmt-api.txt
@@ -815,6 +815,34 @@ Unblock Device Command
=A0 =A0 =A0 or failure.


+Read Tx Power Level Command
+=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D
+
+ =A0 =A0 Command Code: =A0 =A0 =A0 =A0 =A0 0x0028
how is this suppose to work. This command and Set Device ID are suppos=
e
quoted
quoted
to have the same command code?
Ah you're right I missed that. I'll put 0x29 then.
quoted
quoted
+ =A0 =A0 Controller Index: =A0 =A0 =A0 <controller id>
+ =A0 =A0 Command Parameters: =A0 =A0 Address (6 Octets)
+ =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Address_Typ=
e (1 Octet)
quoted
quoted
quoted
+ =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Type (1 Oct=
et)
quoted
quoted
quoted
+ =A0 =A0 Return Parameters: =A0 =A0 =A0Address (6 Octets)
+ =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Address_Typ=
e (1 Octet)
quoted
quoted
quoted
+ =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Status (1 O=
ctet)
quoted
quoted
quoted
+ =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 =A0 Level (1 Oc=
tet)
quoted
quoted
quoted
+
+ =A0 =A0 Possible values for the Address_Type parameter:
+ =A0 =A0 =A0 =A0 =A0 =A0 0 =A0 =A0 =A0 BR/EDR
+ =A0 =A0 =A0 =A0 =A0 =A0 1 =A0 =A0 =A0 LE Public
+ =A0 =A0 =A0 =A0 =A0 =A0 2 =A0 =A0 =A0 LE Random
+
+ =A0 =A0 Possible values for the Type parameter:
+ =A0 =A0 =A0 =A0 =A0 =A0 0 =A0 =A0 =A0 Current Transmit Power Level
+ =A0 =A0 =A0 =A0 =A0 =A0 1 =A0 =A0 =A0 Maximum Transmit Power Level
Which ones do you care about? And why not just read both and return bo=
th
quoted
quoted
at the same time.

I think that I made this pretty clear multiple times already. The mgmt
API is not for stuffing random HCI commands into it. Please explain yo=
ur
quoted
quoted
usage pattern of the results clearly.

Who is triggering this command and who is consuming the results?
Well the proximity reporter and proximity monitor profiles are the
ones using this (with LE connections only). The proximity monitor can
query the reporter for the Tx power level. The spec claims there's no
point in polling for this, as the value doesn't change during an LE
connection.
so why are we not just reading that value when creating a LE connection?
What is the penalty for doing it on every LE connection?
Well presumably it should only be read when the TPS profile if
enabled. The cost is sending another command to the controller on each
connection. Not sure it's very high.
Maybe we can even integrate it into the "device connected" event, and
just read it for all connecting devices.

I guess it's a matter of personal preference.

I think this API is better for future proofing - it gives the caller
the option to get the Tx power for BR/EDR devices as well, at
arbitrary times (since it can change during a BR connection).
Some earlier emails suggested it might be useful.
quoted
Both profiles only care about the current Tx power level. I added the
type for flexibility. It can be removed of course.

In the proposed implementation the reporter reads this value when a
device connects and caches it. When a remote device asks for this
value (via an ATT read as part of the TPS profile), we return the
cached value.
So it gets always read anyway.
Only when TPS server is enabled.

Arik
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help