Re: How to past connect complete event status (page timeout) to apps
From: Luiz Augusto von Dentz <luiz.dentz@gmail.com>
Date: 2010-07-23 20:15:30
Hi, On Fri, Jul 23, 2010 at 8:48 PM, Ed Tsang [off-list ref] wrote:
Hi, I tried to implement my apps to do different things depend on the failed connection attempt. On Hci dump I could saw the connect complete status is different depend on the actual failure (e.g. 0x10 accept timeout, 0x06, PIN missing, 0x04 page timeout). But the apps (base on obex-client) is not able to see those status code. The obex-client attempt a sdp_connect and then g_io_add_watch. On the callback, we could see the G_IO_ERROR but I could not figure out a way to get more detail on the failed condition. I tried look into the Bluez and could not figure what to change to pass those connect event status up.. Anyone could offer some advise/hint...
Well first you will not get the same error on the socket, they will be
translated to errno but the errors will be very similar e.g: page
timeout is mapped to EHOSTDOWN.
But it seems we have a bug in obex-client, basically we need to check
SO_ERROR with getsockopt before proceeding with sdp_set_notify. If you
are fixing this please have a look at btio.c, it should be ok and it
seems ofono does it in a similar fashion:
/* If the user aborted this connect attempt */
if ((cond & G_IO_NVAL) || check_nval(io))
return FALSE;
if (cond & G_IO_OUT) {
int err = 0, sock = g_io_channel_unix_get_fd(io);
socklen_t len = sizeof(err);
if (getsockopt(sock, SOL_SOCKET, SO_ERROR, &err, &len) < 0)
err = errno;
if (err)
g_set_error(&gerr, BT_IO_ERROR,
BT_IO_ERROR_CONNECT_FAILED, "%s (%d)",
strerror(err), err);
} else if (cond & (G_IO_HUP | G_IO_ERR))
g_set_error(&gerr, BT_IO_ERROR, BT_IO_ERROR_CONNECT_FAILED,
"HUP or ERR on socket");
--
Luiz Augusto von Dentz
Computer Engineer