Thread (26 messages) 26 messages, 6 authors, 2003-07-22

RE: [Bluez-devel] Qualification testing - rfcomm

From: Daryl Van Vorst <hidden>
Date: 2003-07-08 23:23:12

James,

Unfortunately I'm not going to be of much help with SCO testing...  We've
been doing our testing with Cetecom (they're on the CC list).

It may be possible for you to arrange something with them if you (or someon=
e
else) are making a product. Contact Ben Ko (benjamin.ko@CetecomUSA.com) if
you'd like to discuss it.

-Daryl.
-----Original Message-----
From: bluez-devel-admin@lists.sourceforge.net=20
[mailto:bluez-devel-admin@lists.sourceforge.net] On Behalf Of=20
James Courtier-Dutton
Sent: July 8, 2003 2:47 PM
To: Daryl Van Vorst
Cc: BlueZ Mailing List; 'Marcel Holtmann'
Subject: Re: [Bluez-devel] Qualification testing - rfcomm
=20
=20
Daryl Van Vorst wrote:
quoted
Marcel,
=20
Finally got some results on those latest rfcomm changes for=20
qualification. Looks like there are a few more problems. :(=20
 But we're=20
quoted
close. :)
=20
TP/RFC/BV-09-C:
"Verify that the IUT handles flow control correctly when=20
the Tester,=20
quoted
acting as a device conforming to Bluetooth version 1.0B,=20
controls the=20
quoted
data flow using the Modem Status Command. The IUT's device=20
role is of=20
quoted
no importance."
=20
The command and console output:
=20
root@jack-00000000:~>./rctest -s -P 1 -b 20 00:A0:96:1F:83:71
rctest[351]: Connected
rctest[351]: Sending ...
rctest[351]: Send failed. Resource temporarily unavailable(11)
=20
The IUT sends data in 5 frames, then stops for aboue 20s,=20
then sends 5=20
quoted
more, then stops, etc. Technically, this test passed because we did=20
stop sending data after the tester send MSC stop to the IUT. But=20
something's clearly not right.
=20
There is an hcidump of the session attached.
=20
TP/RFC/BV-12-C:
"Verify that the IUT handles aggregate flow control=20
correctly when the=20
quoted
Tester, acting as a device conforming to Bleutooth version 1.0B,=20
controls the data flow using the Flow Control on/off=20
commands FCon and=20
quoted
FCoff. The IUT's device role is of no importance."
=20
The command and console output:
=20
root@jack-00000000:~>./rctest -s -P 1 -b 20 00:A0:96:1F:83:71
rctest[362]: Connected
rctest[362]: Sending ...
rfcomm_recv_mcc: Unknown control type 0x18
rfcomm_recv_mcc: Unknown control type 0x28
=20
The IUT does not respond to FCoff with FCoff, and continues sending=20
data. It also does not respond to FCon with FCon.
=20
There is an hcidump of the session attached.
=20
-Daryl.
=20
Any chance of doing some tests with SCO ?
It might help us with some of the currently problems there=20
are with SCO=20
and usb dongles.
Cheers
James
=20
=20
=20
-------------------------------------------------------
This SF.Net email sponsored by: Parasoft
Error proof Web apps, automate testing & more.
Download & eval WebKing and get a free book.=20
www.parasoft.com/bulletproofapps=20
_______________________________________________
Bluez-devel mailing list
Bluez-devel@lists.sourceforge.net=20
https://lists.sourceforge.net/lists/listinfo/b> luez-devel
=20
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help