From: Jan Höppner <hoeppner@linux.ibm.com>
During online processing and setting up a DASD device, the configuration
data for operational paths is read and validated two times
(dasd_eckd_read_conf()). The first time to provide information that are
necessary for the LCU setup. A second time after the LCU setup as a
device might report different configuration data then.
When the configuration setup for each operational path is being
validated, an initial call to dasd_eckd_clear_conf_data() is issued.
This call wipes all previously available configuration data and path
information for each path.
However, the operational path mask is not updated during this process.
As a result, the stored operational path mask might no longer correspond
to the operational paths mask reported by the CIO layer, as several
paths might be gone between the two dasd_eckd_read_conf() calls.
This inconsistency leads to more severe issues in later path handling
changes. Fix this by removing the channel paths from the operational
path mask during the dasd_eckd_clear_conf_data() call.
Signed-off-by: Jan Höppner <hoeppner@linux.ibm.com>
Reviewed-by: Stefan Haberland <sth@linux.ibm.com>
Signed-off-by: Stefan Haberland <sth@linux.ibm.com>
---
drivers/s390/block/dasd_eckd.c | 1 +
1 file changed, 1 insertion(+)
diff --git a/drivers/s390/block/dasd_eckd.c b/drivers/s390/block/dasd_eckd.c
index 3ff7b532a5bf..3273b26b25b0 100644
--- a/drivers/s390/block/dasd_eckd.c
+++ b/drivers/s390/block/dasd_eckd.c
@@ -1034,6 +1034,7 @@ static void dasd_eckd_clear_conf_data(struct dasd_device *device)
device->path[i].cssid = 0;
device->path[i].ssid = 0;
device->path[i].chpid = 0;
+ dasd_path_notoper(device, i);
}
}
--
2.17.1