On 23.03.2026 14:58:21, Ciprian Costea wrote:
From: Ciprian Marian Costea <ciprianmarian.costea@oss.nxp.com>
This patch series adds FlexCAN support for the NXP S32N79 SoC.
The S32N79 is an automotive-grade processor from NXP with multiple
FlexCAN instances. The FlexCAN IP integration on S32N79 differs from
other SoCs in the interrupt routing - it uses two separate interrupt
lines:
- one interrupt for mailboxes 0-127
- one interrupt for bus error detection and device state changes
The CAN controllers are connected through an irqsteer interrupt
controller in the RCU (Resource Control Unit) domain.
This series:
1. Splits flexcan_irq() into dedicated handlers for multi-IRQ platforms
2. Adds dt-bindings documentation for S32N79 FlexCAN
3. Introduces FLEXCAN_QUIRK_IRQ_BERR to handle the two-interrupt
configuration
4. Adds S32N79 device data and compatible string to the driver
5. Adds FlexCAN device tree nodes for S32N79 SoC
6. Enables FlexCAN devices on the S32N79-RDB board
Can you please add support for multiple IRQs to
flexcan_chip_interrupts_enable().
regards,
Marc
--
Pengutronix e.K. | Marc Kleine-Budde |
Embedded Linux | https://www.pengutronix.de |
Vertretung Nürnberg | Phone: +49-5121-206917-129 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-9 |