Re: [PATCH v5 3/4] firmware: psci: Read and use vendor reset types
From: Elliot Berman <hidden>
Date: 2024-08-15 18:09:39
Also in:
linux-arm-msm, linux-devicetree, linux-pm, lkml
On Thu, Aug 15, 2024 at 04:40:55PM +0200, Lorenzo Pieralisi wrote:
On Mon, Aug 12, 2024 at 11:46:08PM +0530, Shivendra Pratap wrote:quoted
On 8/9/2024 10:28 PM, Elliot Berman wrote:quoted
On Fri, Aug 09, 2024 at 03:30:38PM +0200, Lorenzo Pieralisi wrote:quoted
On Wed, Aug 07, 2024 at 11:10:50AM -0700, Elliot Berman wrote: [...]quoted
quoted
quoted
+static void psci_vendor_sys_reset2(unsigned long action, void *data)'action' is unused and therefore it is not really needed.quoted
+{ + const char *cmd = data; + unsigned long ret; + size_t i; + + for (i = 0; i < num_psci_reset_params; i++) { + if (!strcmp(psci_reset_params[i].mode, cmd)) { + ret = invoke_psci_fn(PSCI_FN_NATIVE(1_1, SYSTEM_RESET2), + psci_reset_params[i].reset_type, + psci_reset_params[i].cookie, 0); + pr_err("failed to perform reset \"%s\": %ld\n", + cmd, (long)ret); + } + } +} + static int psci_sys_reset(struct notifier_block *nb, unsigned long action, void *data) { + if (data && num_psci_reset_params)So, reboot_mode here is basically ignored; if there is a vendor defined reset, we fire it off. I think Mark mentioned his concerns earlier related to REBOOT_* mode and reset type (granted, the context was different): https://lore.kernel.org/all/20200320120105.GA36658@C02TD0UTHF1T.local/ (local) I would like to understand if this is the right thing to do before accepting this patchset.I don't have any concerns to move this part below checking reboot_mode. Or, I could add reboot_mode == REBOOT_COLD check.The question is how can we map vendor specific reboot magic to Linux reboot modes sensibly in generic PSCI code - that's by definition vendor specific.I don't think it's a reasonable thing to do. "reboot bootloader" or "reboot edl" don't make sense to the Linux reboot modes. I believe the Linux reboot modes enum is oriented to perspective of Linux itself and the vendor resets are oriented towards behavior of the SoC. Thanks, ElliotAgree. from perspective of linux reboot modes, kernel's current implementation in reset path is like: __ #1 If reboot_mode is WARM/SOFT and PSCI_SYSRESET2 is supported Call PSCI - SYSTEM_RESET2 - ARCH RESET #2 ELSE Call PSCI - SYSTEM_RESET COLD RESET ___ ARM SPECS for PSCI SYSTEM_RESET2 This function extends SYSTEM_RESET. It provides: • ARCH RESET: set Bit[31] to 0 = > This is already in place in condition #1. • vendor-specific resets: set Bit[31] to 1. = > current patchset adds this part before kernel's reboot_mode reset at #0. In current patchset, we see a condition added at #0-psci_vendor_reset2 being called before kernel’s current reboot_mode condition and it can take any action only if all below conditions are satisfied. - PSCI SYSTEM_RESET2 is supported. - psci dt node defines an entry "bootloader" as a reboot-modes. - User issues reboot with a command say - (reboot bootloader). - If vendor reset fails, default reboot mode will execute as is. Don't see if we will skip or break the kernel reboot_mode flow with this patch. Also if user issues reboot <cmd> and <cmd> is supported on SOC vendor reset psci node, should cmd take precedence over kernel reboot mode enum? may be yes?Please wrap lines when replying. I don't think it is a matter of precedence. reboot_mode and the reboot command passed to the reboot() syscall are there for different (?) reasons. What I am asking is whether it is always safe to execute a PSCI vendor reset irrispective of the reboot_mode value.
The only way I see it to be unsafe is we need some other driver using the reboot_mode to configure something and then the PSCI vendor reset being incompatible with whatever that other driver did. I don't see that happens today, so it is up to us to decide what the policy ought to be. The PSCI spec doesn't help us here because the reboot_mode enum is totally a Linux construct. In my opinion, firmware should be able to deal with whatever the driver did or (less ideal) the driver need to be aware of the PSCI vendor resets. Thus, it would be always safe to execute a PSCI vendor reset regardless of the reboot_mode value. Thanks, Elliot