Re: [PATCH net-next v5 2/7] net: phylink: add rxc_always_on flag to phylink_pcs

From
Andrew Lunn <andrew@lunn.ch>
Date
2024-03-04 13:40:18
Also in
linux-renesas-soc, netdev
Reply to
Romain Gantois, 2024-03-01
On Fri, Mar 01, 2024 at 04:34:59PM +0100, Romain Gantois wrote:
Some MAC drivers (e.g. stmmac) require a continuous receive clock signal to
be generated by a PCS that is handled by a standalone PCS driver.

Such a PCS driver does not have access to a PHY device, thus cannot check
the PHY_F_RXC_ALWAYS_ON flag. They cannot check max_requires_rxc in the
phylink config either, since it is a private member. Therefore, a new flag
is needed to signal to the PCS that it should keep the RX clock signal up
at all times.

Suggested-by: Russell King <linux@armlinux.org.uk>
Signed-off-by: Romain Gantois <romain.gantois@bootlin.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>

    Andrew

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel