On Mon, Feb 12, 2018 at 8:42 AM, [off-list ref] wrote:
From: Patrice Chotard <redacted>
Remove leading 0x and 0s from bindings notation
Add missing unit-address and remove some which are useless.
This allows to fix several warnings like :
Warning (unit_address_vs_reg): Node XXXX has a reg or ranges property, but no unit name
Warning (simple_bus_reg): Node XXXX simple-bus unit address format error, expected "123456"
Warning (unit_address_vs_reg): Node XXXX has a unit name, but no reg property
Signed-off-by: Patrice Chotard <redacted>
---
[...]
quoted hunk ↗ jump to hunk
diff --git a/arch/arm/boot/dts/stih407-pinctrl.dtsi b/arch/arm/boot/dts/stih407-pinctrl.dtsi
index a29090077fdf..53c6888d1fc0 100644
--- a/arch/arm/boot/dts/stih407-pinctrl.dtsi
+++ b/arch/arm/boot/dts/stih407-pinctrl.dtsi
@@ -45,7 +45,7 @@
};
soc {
- pin-controller-sbc {
+ pin-controller-sbc at 961f080 {
While you're here changing the node name, these all should be "pinctrl at ..."
With that,
Reviewed-by: Rob Herring <robh@kernel.org>