Thread (46 messages) 46 messages, 8 authors, 2016-03-16

[PATCH v4 09/24] regulator: pwm: use pwm_get/set_default_xxx() helpers where appropriate

From: Boris Brezillon <hidden>
Date: 2015-12-02 10:37:39
Also in: linux-clk, linux-fbdev, linux-input, linux-leds, linux-pwm, linux-rockchip, lkml

Hi,

On Mon, 16 Nov 2015 18:42:38 +0000
Mark Brown [off-list ref] wrote:
On Mon, Nov 16, 2015 at 01:23:59PM +0100, Boris Brezillon wrote:
quoted
Mark Brown [off-list ref] wrote:
quoted
On Mon, Nov 16, 2015 at 09:56:32AM +0100, Boris Brezillon wrote:
quoted
quoted
quoted
-	pwm_reg_period = pwm_get_period(drvdata->pwm);
+	pwm_reg_period = pwm_get_default_period(drvdata->pwm);
quoted
quoted
It's not clear to me that we're not looking for the current period here
or in the other use.  Won't configuring based on a period other than the
one that has been set give the wrong answer?
quoted
Hm, maybe that's naming problem. What I call the 'default' period here
is actually the period configured in your board file (using a PWM lookup
table) or your DT. This value represent the period requested by the PWM
user not a default value specified by the PWM chip driver.
quoted
The reason we're not using the 'current' period value is because it may
have been set by the bootloader, and may be inappropriate for our use
case (ie. the period may be to small to represent the different
voltages).
quoted
ITOH, we're using the current period value when calculating the current
voltage, because we want to get the correct voltage value, and the PWM
device may still use the configuration set by the bootloader (not the
default one specified in your board or DT files).
quoted
I hope this clarifies the differences between the current and default
period, and why we should use the default value here.
To be honest I'm still a bit confused here.  When do we actually apply
the default setting and why do we keep on having to constantly override
it rather than doing this once at boot?  It feels wrong to be using it
every time we set anything.  I'd expect it to be something we only need
to do at probe time or which would automatically be handled by the PWM
framework (but that'd have issues changing the state and potentially
breaking things if done in an uncoordiated fashion).
Thierry, I didn't hear from you after the long discussion we had on IRC
a few weeks ago.
The conclusion of this discussion was that using
pwm_get_default_period() was not acceptable (even after renaming it
differently, like pwm_get_reference_period()), because it was
disturbing to get the default/reference period each time we wanted to
configure the PWM differently.
Another suggestion was to automatically reconfigure the PWM duty_ns
value based on the initial PWM state (retrieved through hardware
readout) and the default period value (specified in the PWM lookup table
or the DT). But this implied supporting hardware readout in all PWM
drivers, which prevents a smooth migration to this new approach.

I also proposed to provide helpers to hide the duty cycle to active
time calculation in the PWM core, so that PWM users just have to choose
their scale (percent, or any other custom scale) and set their duty
cycle based on this scale instead of specifying an active/on time in
nanosecond. You didn't seem to like this idea, but I gave it a try
(see here [1]), and think it might be worth looking at it.

The commit you should look at are [2], [3] and [4], and the idea is to
clarify the notion of duty-cycle, which, according to wikipedia [5]
(and a lot of other references) is supposed to be expressed in a
relative unit (percent, or any other scale as said earlier).
After renaming the pwm_set/get_duty_cycle() helpers into
pwm_set/get_active_time() we can define a new pwm_set_duty_cycle()
helper to let the PWM user configure its PWM device relatively to a
chosen scale, without asking him to choose the PWM period (the
conversion is done based on the default/reference period).
The pwm_get_duty_cycle() is doing the reverse conversion: it returns the
duty-cycle expressed relatively to the scale (here the current PWM
period is used to handle the case where the PWM user hasn't configure
the PWM yet, but want to retrieve the current duty-cycle extracted from
hardware readout).

Please let me know what you think of this approach, and if you're happy
with it I'll rework my series accordingly.

Best Regards,

Boris

[1]https://github.com/bbrezillon/linux-rk/commits/atomic-pwm-alt
[2]https://github.com/bbrezillon/linux-rk/commit/d7d4d04e147d4ec349c59f70e141877661930c6d
[3]https://github.com/bbrezillon/linux-rk/commit/66ce78f308f3eb1a9c536689352f208fd51c9030
[4]https://github.com/bbrezillon/linux-rk/commit/07882a2dd21f0d17d83640ff55204cc7a7d4c8f7
[5]https://en.wikipedia.org/wiki/Duty_cycle

-- 
Boris Brezillon, Free Electrons
Embedded Linux and Kernel engineering
http://free-electrons.com
Keyboard shortcuts