Thread (25 messages) 25 messages, 6 authors, 2013-12-06

[PATCH v4 2/3] regulator: tps6586x: add and use correct voltage table

From: stefan@agner.ch (Stefan Agner)
Date: 2013-12-04 14:12:23
Also in: linux-tegra, lkml

Am 2013-12-04 13:14, schrieb Mark Brown:
On Tue, Dec 03, 2013 at 11:18:47PM +0100, Stefan Agner wrote:
quoted
Depending on the regulator version, the voltage table might be
different. Use version specific regulator tables in order to select
correct voltage table. For the following regulator versions different
voltage tables are now used:
Acked-by: Mark Brown <redacted>

I won't apply since I think that patch 3 needs to go along with this,
unless people decide the regulator tree is the easiest way to merge.
I merged the dependent DT changes into that patch, so from my side,
patch 3 don't needs to go along with this...