Jon,

[cutting out realms of context!]

On Fri, Jul 13, 2012 at 02:54:59PM +0100, Jon Hunter wrote:
Another proposal I also thought of is re-working the flags to describe
the HW mode to be used when turning on the CLKDM, when the CLKDM is
active and when the CLKDM is shut down. So instead of saying what modes
the CLKDM supports, specify what modes should be used for pre-ON (i.e.
turn ON), ON and OFF. Right now software is trying to decide for us by
what is available (which is ideal) but makes working around such nuances
a little more painful.

By the way, I did do some testing on OMAP3, but I don't recall now
whether I was having such problems with OMAP3. I need to go back and
test perf again on OMAP3 to see if such a flag is needed.
If you do test on OMAP3, please kill the OMAP3_EMU option as I think this
has the effect of keeping the EMU power domain up via the etm code (look at
etb_probe).

Will

---8<---
diff --git a/arch/arm/Kconfig b/arch/arm/Kconfig
index a91009c..d02054c 100644
--- a/arch/arm/Kconfig
+++ b/arch/arm/Kconfig
@@ -1139,8 +1139,7 @@ config XSCALE_PMU
        default y
 
 config CPU_HAS_PMU
-       depends on (CPU_V6 || CPU_V6K || CPU_V7 || XSCALE_PMU) && \
-                  (!ARCH_OMAP3 || OMAP3_EMU)
+       depends on (CPU_V6 || CPU_V6K || CPU_V7 || XSCALE_PMU)
        default y