Tero Kristo [off-list ref] writes:
On Fri, 2012-03-02 at 14:42 -0800, Kevin Hilman wrote:
quoted
When using the SMPS regulators to scale voltages, the regulator
framework may pass a minimum voltage that is not an exact OPP voltage.
For the VC/VP controlled voltage domains, we must ensure that the
voltage requested is the exact voltage from the OPP table. This is
especially critical when using SR.
To fix, voltdm_scale() uses the target voltage passed to walk through
the OPP voltages until it finds a voltage that is >= one of the OPP
voltages.
I have just one question to this, how about smartreflex class1p5? Do we
have any plans for that one? The old implementation at least was using
voltdm_scale, so if we modify this function, smartreflex class1p5
doesn't work anymore.
Since it's not in mainline, that is not my concern at the moment. We
can worry about SR1.5 when I someone is motivated to push it upstream.
Otherwise this patch looks good to me.
Thanks for looking.
Kevin