Thread (7 messages) flat view 7 messages, 3 authors, 2021-09-14

Re: [PATCH 1/2] power: supply: max17042_battery: Clear status bits in interrupt handler

From: Krzysztof Kozlowski <hidden>
Date: 2021-09-13 13:05:09
Also in: linux-pm, lkml

On 12/09/2021 22:54, Sebastian Krzyszkowiak wrote:
quoted hunk ↗ jump to hunk
The gauge requires us to clear the status bits manually for some alerts
to be properly dismissed. Previously the IRQ was configured to react only
on falling edge, which wasn't technically correct (the ALRT line is active
low), but it had a happy side-effect of preventing interrupt storms
on uncleared alerts from happening.

Fixes: 7fbf6b731bca ("power: supply: max17042: Do not enforce (incorrect) interrupt trigger type")
Cc: <redacted>
Signed-off-by: Sebastian Krzyszkowiak <sebastian.krzyszkowiak@puri.sm>
---
 drivers/power/supply/max17042_battery.c | 3 +++
 1 file changed, 3 insertions(+)
diff --git a/drivers/power/supply/max17042_battery.c b/drivers/power/supply/max17042_battery.c
index 8dffae76b6a3..c53980c8432a 100644
--- a/drivers/power/supply/max17042_battery.c
+++ b/drivers/power/supply/max17042_battery.c
@@ -876,6 +876,9 @@ static irqreturn_t max17042_thread_handler(int id, void *dev)
 		max17042_set_soc_threshold(chip, 1);
 	}
 
+	regmap_clear_bits(chip->regmap, MAX17042_STATUS,
+			  0xFFFF & ~(STATUS_POR_BIT | STATUS_BST_BIT));
+
Are you sure that this was the reason of interrupt storm? Not incorrect
SoC value (read from register for ModelGauge m3 while not configuring
fuel gauge model).

You should only clear bits which you are awaken for... Have in mind that
in DT-configuration the fuel gauge is most likely broken by missing
configuration. With alert enabled, several other config fields should be
cleared.

Best regards,
Krzysztof