Thread (3 messages) 3 messages, 2 authors, 2016-12-29

Re: [RESEND] thermal: hwmon: Properly report critical temperature in sysfs

From: Zhang Rui <rui.zhang@intel.com>
Date: 2016-12-29 11:43:55
Also in: linux-pm, lkml

On Wed, 2016-12-28 at 19:35 +0200, Krzysztof Kozlowski wrote:
In the critical sysfs entry the thermal hwmon was returning wrong
temperature to the user-space.  It was reporting the temperature of
the
first trip point instead of the temperature of critical trip point.

For example:
	/sys/class/hwmon/hwmon0/temp1_crit:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_temp:50000
	/sys/class/thermal/thermal_zone0/trip_point_0_type:active
	/sys/class/thermal/thermal_zone0/trip_point_3_temp:120000
	/sys/class/thermal/thermal_zone0/trip_point_3_type:critical

Since commit e68b16abd91d ("thermal: add hwmon sysfs I/F") the driver
have been registering a sysfs entry if get_crit_temp() callback was
provided.  However when accessed, it was calling get_trip_temp()
instead
of the get_crit_temp().

Fixes: e68b16abd91d ("thermal: add hwmon sysfs I/F")
Cc: <redacted>
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
The patch is already in upstream kernel.

thanks,
rui
quoted hunk ↗ jump to hunk
---
 drivers/thermal/thermal_hwmon.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/thermal/thermal_hwmon.c
b/drivers/thermal/thermal_hwmon.c
index c41c7742903a..2dcd4194d103 100644
--- a/drivers/thermal/thermal_hwmon.c
+++ b/drivers/thermal/thermal_hwmon.c
@@ -98,7 +98,7 @@ temp_crit_show(struct device *dev, struct
device_attribute *attr, char *buf)
 	int temperature;
 	int ret;
 
-	ret = tz->ops->get_trip_temp(tz, 0, &temperature);
+	ret = tz->ops->get_crit_temp(tz, &temperature);
 	if (ret)
 		return ret;
 