Thread (33 messages) 33 messages, 3 authors, 16d ago

Re: [PATCH net 04/12] net: systemport: Fix missing phy-handle parsing for non-fixed PHYs

flat view

From: Nicolai Buchwitz <nb@tipi-net.de>
Date: 2026-09-22 08:50:11
Also in: lkml

Hi Florian

On 22.9.2026 01:12, Florian Fainelli wrote:
In bcm_sysport_probe(), priv->phy_dn is only initialized if the device
tree node has a fixed-link configuration (of_phy_is_fixed_link). When
connecting to a discrete MDIO-attached PHY referenced via 'phy-handle',
priv->phy_dn remains NULL. This causes of_phy_connect() during
bcm_sysport_open() to fail with -ENODEV since of_phy_find_device(NULL)
returns NULL.

Fix this by parsing 'phy-handle' via of_parse_phandle() and falling back
to of_phy_is_fixed_link(). Ensure proper of_node_get() and of_node_put()
refcounting lifecycle on both error unwinding and module remove paths.

Fixes: 186534a3f832 ("net: systemport: use the new fixed PHY helpers")
Assisted-by: LLM
Signed-off-by: Florian Fainelli <florian.fainelli@broadcom.com>
---
[...]
Not sure this qualifies as a fix, the driver never parsed phy-handle. Maybe net-next material?

Regards
Nicolai