Hello:
This patch was applied to netdev/net.git (main)
by Jakub Kicinski [off-list ref]:
On Sat, 5 Sep 2026 15:02:32 +0200 you wrote:
KSZ8851 errata sheet DS80000716D-page 4 Module 3 [1] states that,
when issuing a software power-down (PMECR[1:0] = 10) followed by a
power-on (PMECR[1:0] = 00), the receiver circuit can fail to start
properly preventing communication. The Transmitter will still send
data, but no data will be received.
The errata sheet also includes a workaround, which states that,
it is recommended that the software power-down feature not be used.
[...]
Here is the summary with links:
- [net,v2] net: ks8851: Fix receiver error in 100BASE-TX mode following software power-down
https://git.kernel.org/netdev/net/c/66ef5adb7544
You are awesome, thank you!
--
Deet-doot-dot, I am a bot.
https://korg.docs.kernel.org/patchwork/pwbot.html