Re: [PATCH v6 net-next 0/4] PHC support in ENA driver
From: Maciek Machnikowski <hidden>
Date: 2025-02-11 07:58:51
From: Maciek Machnikowski <hidden>
Date: 2025-02-11 07:58:51
On 2/11/2025 1:46 AM, Jakub Kicinski wrote:
On Sun, 9 Feb 2025 12:33:24 +0000 Vadim Fedorenko wrote:quoted
Yes, we have seen this patchset, and we were thinking of how to generalize error_bound property, which was removed from the latest version unfortunately. But it's a good point to look at it once again in terms of our prototype, thanks!I was wondering whether they have a user space "time extrapolation component" which we should try to be compatible with. Perhaps they just expect that the user will sync system time.
error_bound has a different purpose - it tries to get the "baseline" clock accuracy from the HW. The number returned here is needed to calculate the uncertainty, not to extrapolate. And yes - AFIK AWS suggests system time sync for EC2 instances [1] [1] https://docs.aws.amazon.com/AWSEC2/latest/UserGuide/configure-ec2-ntp.html