Re: [PATCH net-next 00/12] Add support for PSE port priority

flat view

From: Kory Maincent <kory.maincent@bootlin.com>
Date: 2024-10-18 12:37:10
Also in: linux-doc, lkml

On Fri, 18 Oct 2024 08:14:26 +0200
Oleksij Rempel [off-list ref] wrote:
On Thu, Oct 17, 2024 at 12:35:57PM +0200, Kory Maincent wrote:
quoted
On Tue, 15 Oct 2024 11:43:52 +0200
Kory Maincent [off-list ref] wrote:
  
 [...]  
quoted
quoted
Indeed we will have only static method for PSE controllers not supporting
system power budget management like the TPS2388x or LTC426.
Both method could be supported for "smart" PSE controller like PD692x0.

Let's begin with the static method implementation in the PSE framework for
now. It will need the power domain notion you have talked about.  
While developing the software support for port priority in static method, I
faced an issue.

Supposing we are exceeding the power budget when we plug a new PD.
The port power should not be enabled directly or magic smoke will appear.
So we have to separate the detection part to know the needs of the PD from
the power enable part.

Currently the port power is enabled on the hardware automatically after the
detection process. There is no way to separate power port process and
detection process with the PD692x0 controller and it could be done on the
TPS23881 by configuring it to manual mode but: "The use of this mode is
intended for system diagnostic purposes only in the event that ports cannot
be powered in accordance with the IEEE 802.3bt standard from semiauto or
auto modes." Not sure we want that.

So in fact the workaround you talked about above will be needed for the two
PSE controllers.  
For the TPS23881, "9.1.1.2 Semiauto", seems to be exactly what we wont:
"The port performs detection and classification (if valid detection
occurs) continuously. Registers are updated each time a detection or
classification occurs. The port power is not automatically turned on. A
Power Enable command is required to turn on the port"
I tested reading the assigned class and not the requested class register so I
thought it was not working but indeed it detects the class even if the port
power is off. That's what I was looking for, nice!
Just figured out also that calling pwoff is reseting detection, classification,
power policy... So the port need to be setup again after a pwoff.
 
For PD692x0 controller, i'm not 100% sure. There is "4.3.5 Set Enable/Disable
Channels" command, "Sets individual port Enable (Delivering power
enable) or Disable (Delivering power disable)." 

For my understanding, "Delivering power" is the state after
classification. So, it is what we wont too.
On the PD692x0 there is also a requested class and power value but it stay "to
no class detected value" (0xc) if the port is not enabled.
It did not find a way to detect the class and keep port power off.
 
If, it works in both cases, it would be a more elegant way to go. THe
controller do auto- detection and classification, what we should do in
the software is do decide if the PD can be enabled based on
classification results, priority and available budget.
quoted
quoted
Both methods have their pros and cons. Since the dynamic method is not
always desirable, and if there's no way to disable it in the PD692x0's
firmware, one potential workaround could be handling the budget in
software and dynamically setting per-port limits. For instance, with a
total budget of 300W and unused ports, we could initially set 95W limits
per port. As high-priority PDs (e.g., three 95W devices) are powered, we
could dynamically reduce the power limit on the remaining ports to 15W,
ensuring that no device exceeds that classification threshold.  
We would set port overcurrent limit for all unpowered ports when the power
budget available is less than max PI power 100W as you described.
If a new PD plugged exceed the overcurrent limit then it will raise an
interrupt and we could deal with the power budget to turn off low priority
ports at that time.   
quoted
Mmh in fact I could not know if the overcurrent event interrupt comes from a
newly plugged PD or not.  
Hm..  in case of PD692x0, may be using event counters?
Counters? I don't see how.
quoted
An option: When we get new PD device plug interrupt event, we wait the end
of classification time (Tpon 400ms) and read the interrupt states again to
know if there is an overcurrent or not on the port.  
Let's try Semiauto mode for TPS23881 first, I assume it is designed
exactly for this use case.
Yes,
And then, test if PD692x0 supports a way to disable auto power delivery
in the 4.3.5 command.
I don't have this 4.3.5 command. Are you refering to another document than the
communication protocol version 3.55 document?

Regards,
-- 
Köry Maincent, Bootlin
Embedded Linux and kernel engineering
https://bootlin.com