On Fri, Mar 01, 2024 at 04:34:59PM +0100, Romain Gantois wrote:
Some MAC drivers (e.g. stmmac) require a continuous receive clock signal to
be generated by a PCS that is handled by a standalone PCS driver.
Such a PCS driver does not have access to a PHY device, thus cannot check
the PHY_F_RXC_ALWAYS_ON flag. They cannot check max_requires_rxc in the
phylink config either, since it is a private member. Therefore, a new flag
is needed to signal to the PCS that it should keep the RX clock signal up
at all times.
Suggested-by: Russell King <linux@armlinux.org.uk>
Given that this contains some of my code, this is slightly more than
"suggested by", it's probably more accurately co-developed-by.
All the same comments apply to this attributation as the sign-off in
patch 1.
--
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 80Mbps down 10Mbps up. Decent connectivity at last!