Thread (8 messages) 8 messages, 2 authors, 2022-02-19

Re: [PATCH net-next 1/4] ionic: catch transition back to RUNNING with fw_generation 0

From: Shannon Nelson <hidden>
Date: 2022-02-18 17:30:50

On 2/17/22 8:12 PM, Jakub Kicinski wrote:
On Thu, 17 Feb 2022 14:02:49 -0800 Shannon Nelson wrote:
quoted
In some graceful updates that get initially triggered by the
RESET event, especially with older firmware, the fw_generation
bits don't change but the fw_status is seen to go to 0 then back
to 1.  However, the driver didn't perform the restart, remained
waiting for fw_generation to change, and got left in limbo.

This is because the clearing of idev->fw_status_ready to 0
didn't happen correctly as it was buried in the transition
trigger: since the transition down was triggered not here
but in the RESET event handler, the clear to 0 didn't happen,
so the transition back to 1 wasn't detected.

Fix this particular case by bringing the setting of
idev->fw_status_ready back out to where it was before.

Fixes: 398d1e37f960 ("ionic: add FW_STOPPING state")
Signed-off-by: Shannon Nelson <redacted>
This looks like a fix, and should go separately to net.
Is there a reason behind posting together? The other patches
don't even depend on this one.
I posted it to net-next because the patch it is fixing is still in 
net-next and not in net or stable yet.

sln