Re: [PATCH v3 03/13] net: phy: at803x: improve the WOL feature
From: Jie Luo <hidden>
Date: 2021-10-19 11:47:00
Also in:
lkml
On 10/19/2021 2:41 AM, Andrew Lunn wrote:
quoted
@@ -348,18 +349,29 @@ static int at803x_set_wol(struct phy_device *phydev, phy_write_mmd(phydev, MDIO_MMD_PCS, offsets[i], mac[(i * 2) + 1] | (mac[(i * 2)] << 8)); + /* Enable WOL function */ + ret = phy_modify_mmd(phydev, MDIO_MMD_PCS, AT803X_PHY_MMD3_WOL_CTRL, + 0, AT803X_WOL_EN); + if (ret) + return ret; + /* Enable WOL interrupt */ ret = phy_modify(phydev, AT803X_INTR_ENABLE, 0, AT803X_INTR_ENABLE_WOL); if (ret) return ret; - value = phy_read(phydev, AT803X_INTR_STATUS); } else { + /* Disable WoL function */ + ret = phy_modify_mmd(phydev, MDIO_MMD_PCS, AT803X_PHY_MMD3_WOL_CTRL, + AT803X_WOL_EN, 0); + if (ret) + return ret; + /* Disable WOL interrupt */ ret = phy_modify(phydev, AT803X_INTR_ENABLE, AT803X_INTR_ENABLE_WOL, 0); if (ret) return ret; - value = phy_read(phydev, AT803X_INTR_STATUS); } - return ret; + /* Clear WOL status */ + return phy_read(phydev, AT803X_INTR_STATUS);It looks like you could be clearing other interrupt bits which have not been serviced yet. Is it possible to clear just WoL?
Hi Andrew, when this register AT803X_INTR_STATUS bits are cleared after read, we can't clear only WOL interrupt here.
Also, you are returning the contents of the interrupt status register? You should probably be returning 0 if the read was successful.
thanks for this comments, will correct it in the next patch set.
Andrew