Thread (14 messages) 14 messages, 2 authors, 2021-06-06

Re: [RFC net-next 0/2] Introduce MDIO probe order C45 over C22

flat view

From: Andrew Lunn <andrew@lunn.ch>
Date: 2021-05-25 13:34:40
Also in: lkml

On Tue, May 25, 2021 at 01:58:03PM +0800, Wong Vee Khee wrote:
Synopsys MAC controller is capable of pairing with external PHY devices
that accessible via Clause-22 and Clause-45.

There is a problem when it is paired with Marvell 88E2110 which returns
PHY ID of 0 using get_phy_c22_id(). We can add this check in that
function, but this will break swphy, as swphy_reg_reg() return 0. [1]
Is it possible to identify it is a Marvell PHY? Do any of the other
C22 registers return anything unique? I'm wondering if adding
.match_phy_device to genphy would work to identify it is a Marvell PHY
and not bind to it. Or we can turn it around, make the
.match_phy_device specifically look for the fixed-link device by
putting a magic number in one of the vendor registers.

    Andrew
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help