On Wed, May 26, 2021 at 02:45:53PM +0300, Boris Sukholitko wrote:
Hi Davide, On Tue, May 25, 2021 at 10:35:50PM +0200, Davide Caratti wrote:quoted
On Tue, May 25, 2021 at 06:35:59PM +0300, Boris Sukholitko wrote:
hello Boris, [...]
quoted
quoted
@@ -189,7 +190,8 @@ static int tcf_vlan_init(struct net *net, struct nlattr *nla, push_proto = htons(ETH_P_8021Q); } - if (tb[TCA_VLAN_PUSH_VLAN_PRIORITY]) + push_prio_exists = !!tb[TCA_VLAN_PUSH_VLAN_PRIORITY];when the VLAN tag is pushed, not modified, the value of 'push_prio' is used in the traffic path regardless of the true/false value of 'push_prio_exists'. See below: 50 case TCA_VLAN_ACT_PUSH: 51 err = skb_vlan_push(skb, p->tcfv_push_proto, p->tcfv_push_vid | 52 (p->tcfv_push_prio << VLAN_PRIO_SHIFT));Yes, the tcfv_push_prio is 0 here by default.quoted
So, I think that 'p->push_prio_exists' should be identically set to true when 'v_action' is TCA_VLAN_ACT_PUSH. That would allow a better display of rules once patch 2 of your series is applied: otherwise, 2 rules configuring the same TCA_VLAN_ACT_PUSH rule would be displayed differently, depending on whether userspace provided or not the TCA_VLAN_PUSH_VLAN_PRIORITY attribute set to 0.Sorry for being obtuse, but I was under impression that we want to display priority if and only if it has been set by the userspace.
don't get me wrong, I don't have strong opinions on this (I don't have strong opinions at all :) ). In my understanding, the patch was adding 'push_prio_exists' to allow using 0 in 'p->tcfv_push_prio' in the traffic path, instead of assuming that '0' implies no configuration by the user. My suggestion was just to simplify the end-user dump experience, so that the value of 'p->tcfv_push_prio' is dumped always in case of TCA_VLAN_ACT_PUSH. In this way, rules with equal "behavior" in the traffic path are always dumped in the same way. IOW, # tc action add action vlan push id 42 prio 0 index 1 and # tc action add action vlan push id 42 index 1 do exactly the same thing in the traffic path, so there is no need to dump them differently. On the contrary, these 2 rules: # tc action add action vlan modify id 42 prio 0 index 1 and # tc action add action vlan modify id 42 index 1 don't do the same thing, because packet hitting the first rule will have their priority identically set to 0, while the second one will leave the VLAN priority unmodified. So, I think it makes sense to have different dumps here (that was my comment to your v1). Another small nit - forgive me, I didn't spot it in the first review: not 100% sure, but I think that in tcf_vlan_get_fill_size() we need to avoid accounting for TCA_VLAN_PUSH_VLAN_PRIORITY in case the rule has 'push_prio_exists' equal to false. Otherwise we allocate an extra u8 netlink attribute in case of batch dump. Correct? thanks! -- davide