Re: [PATCH net-next v2 0/2] Add support for DSFP transceiver type
From: Vladyslav Tarasiuk <hidden>
Date: 2021-01-04 15:25:21
On 30-Dec-20 17:36, Andrew Lunn wrote:
On Wed, Dec 30, 2020 at 03:55:02PM +0200, Vladyslav Tarasiuk wrote:quoted
On 29-Dec-20 18:25, Andrew Lunn wrote:quoted
quoted
Hi Andrew, Following this conversation, I wrote some pseudocode checking if I'm on right path here. Please review: struct eeprom_page { u8 page_number; u8 bank_number; u16 offset; u16 data_length; u8 *data; }I'm wondering about offset and data_length, in this context. I would expect you always ask the kernel for the full page, not part of it. Even when user space asks for just part of a page. That keeps you cache management simpler.As far as I know, there may be bytes, which may change on read. For example, clear on read values in CMIS 4.0.Ah, i did not know there were such bits. I will go read the spec. But it should not really matter. If the SFP driver is interested in these bits, it will have to intercept the read and act on the values.
But in case user requests a few bytes from a page with clear-on-read values, reading full page will clear all such bytesfrom user perspective even if they were not requested. Driver may intercept the read, but for user it will look like those bytes were not set. Current user interface allows arbitrary reads, so I wanted to keep this behavior pretty much exactly like it is now - request specific part of a page, get this part without any extra data.
quoted
I wasn't aware of that. It complicates things a bit, should we add a parameter of i2c address? So in this case page 0 will be with i2c address A0h. And if user needs page 0 from i2c address A2h, he will specify it in command line.Not on the command line. You should be able to determine from reading page 0 at A0h is the diagnostics are at A2h or a page of A0h. That is the whole point of this API, we decode the first page, and that tells us what other pages should be available. So adding the i2c address to the netlink message would be sensible. And i would not be too surprised if there are SFPs with proprietary registers on other addresses, which could be interesting to dump, if you can get access to the needed datasheets.
Without command line argument user will not be able to request a single A2h page, for example. He will see it only in some kind of general dump - with human-readable decoder usage or multiple page dump. And same goes forpages on other i2c addresses. How to know what to dump, if user does not provide i2c address and there is no way to know what to request from proprietary SFPs? Thanks, Vlad