[RFC v2 08/19] batman-adv: Add bridge_loop_avoidance mesh genl configuration
From: Sven Eckelmann <hidden>
Date: 2018-11-23 16:13:48
Also in:
batman
Subsystem:
batman advanced, the rest · Maintainers:
Marek Lindner, Simon Wunderlich, Antonio Quartulli, Sven Eckelmann, Linus Torvalds
The mesh interface can try to detect loops in the same mesh caused by (indirectly) bridged mesh/soft-interfaces of different nodes. Some of the loops can also be resolved without breaking the mesh. The BATADV_CMD_SET_MESH/BATADV_CMD_GET_MESH commands allow to set/get the configuration of this feature using the BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE attribute. Setting the u8 to zero will disable this feature and setting it to something else is enabling this feature. Cc: Jiri Pirko <jiri-VPRAkNaXOzVWk0Htik3J/w@public.gmane.org> Signed-off-by: Sven Eckelmann <redacted> --- include/uapi/linux/batman_adv.h | 7 +++++++ net/batman-adv/netlink.c | 17 +++++++++++++++++ 2 files changed, 24 insertions(+)
diff --git a/include/uapi/linux/batman_adv.h b/include/uapi/linux/batman_adv.h
index d209c468..711379ef 100644
--- a/include/uapi/linux/batman_adv.h
+++ b/include/uapi/linux/batman_adv.h@@ -380,6 +380,13 @@ enum batadv_nl_attrs { */ BATADV_ATTR_BONDING, + /** + * @BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE: whether the bridge loop avoidance + * feature is enabled. This feature detects and avoids loops between + * the mesh and devices bridged with the soft interface + */ + BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE, + /* add attributes above here, update the policy in netlink.c */ /**
diff --git a/net/batman-adv/netlink.c b/net/batman-adv/netlink.c
index a836a8f1..95181808 100644
--- a/net/batman-adv/netlink.c
+++ b/net/batman-adv/netlink.c@@ -144,6 +144,7 @@ static const struct nla_policy batadv_netlink_policy[NUM_BATADV_ATTR] = { [BATADV_ATTR_ISOLATION_MARK] = { .type = NLA_U32 }, [BATADV_ATTR_ISOLATION_MASK] = { .type = NLA_U32 }, [BATADV_ATTR_BONDING] = { .type = NLA_U8 }, + [BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE] = { .type = NLA_U8 }, }; /**
@@ -283,6 +284,12 @@ static int batadv_netlink_mesh_put(struct sk_buff *msg, !!atomic_read(&bat_priv->bonding))) goto nla_put_failure; +#ifdef CONFIG_BATMAN_ADV_BLA + if (nla_put_u8(msg, BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE, + !!atomic_read(&bat_priv->bridge_loop_avoidance))) + goto nla_put_failure; +#endif /* CONFIG_BATMAN_ADV_BLA */ + batadv_hardif_put(primary_if); genlmsg_end(msg, hdr);
@@ -396,6 +403,16 @@ static int batadv_netlink_set_mesh(struct sk_buff *skb, struct genl_info *info) atomic_set(&bat_priv->bonding, !!nla_get_u8(attr)); } +#ifdef CONFIG_BATMAN_ADV_BLA + if (info->attrs[BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE]) { + attr = info->attrs[BATADV_ATTR_BRIDGE_LOOP_AVOIDANCE]; + + atomic_set(&bat_priv->bridge_loop_avoidance, + !!nla_get_u8(attr)); + batadv_bla_status_update(bat_priv->soft_iface); + } +#endif /* CONFIG_BATMAN_ADV_BLA */ + batadv_netlink_notify_mesh(bat_priv); return 0;
--
2.19.1