Thread (4 messages) 4 messages, 3 authors, 2018-07-05

Re: [PATCH] [v2] infiniband: i40iw, nes: don't use wall time for TCP sequence numbers

From: Arnd Bergmann <arnd@arndb.de>
Date: 2018-07-05 13:15:55
Also in: linux-rdma, lkml

On Sat, Jun 30, 2018 at 9:00 PM, kbuild test robot [off-list ref] wrote:
Hi Arnd,

I love your patch! Yet something to improve:

[auto build test ERROR on linus/master]
[also build test ERROR on v4.18-rc2 next-20180629]
[if your patch is applied to the wrong git tree, please drop us a note to help improve the system]

url:    https://github.com/0day-ci/linux/commits/Arnd-Bergmann/infiniband-i40iw-nes-don-t-use-wall-time-for-TCP-sequence-numbers/20180627-221142
config: x86_64-randconfig-s2-06302231 (attached as .config)
compiler: gcc-6 (Debian 6.4.0-9) 6.4.0 20171026
reproduce:
        # save the attached .config to linux build tree
        make ARCH=x86_64

All errors (new ones prefixed by >>):

   drivers/infiniband/hw/i40iw/i40iw_cm.o: In function `i40iw_make_cm_node':
quoted
quoted
drivers/infiniband/hw/i40iw/i40iw_cm.c:2232: undefined reference to `secure_tcpv6_seq'
Fixed this now by added a

        depends on IPV6 || !IPV6

dependency in Kconfig. This ensures that with IPV6=m, i40iw cannot be built-in.

Will send v3 after a little more build testing.

      Arnd