Thread (3 messages) flat view 3 messages, 3 authors, 2018-06-05

Re: [PATCH net-next] net: phy: broadcom: Enable 125 MHz clock on LED4 pin for BCM54612E by default.

From: David Miller <davem@davemloft.net>
Date: 2018-06-05 13:43:57

From: Kun Yi <redacted>
Date: Mon,  4 Jun 2018 13:17:04 -0700
BCM54612E have 4 multi-functional LED pins that can be configured
through register setting; the LED4 pin can be configured to a 125MHz
reference clock output by setting the spare register. Since the dedicated
CLK125 reference clock pin is not brought out on the 48-Pin MLP, the LED4
pin is the only pin to provide such function in this package, and therefore
it is beneficial to just enable the reference clock by default.

Signed-off-by: Kun Yi <redacted>
Applied, thank you.