Thread (2 messages) 2 messages, 2 authors, 2018-02-28

Re: [PATCH net-next] r8169: fix interrupt number after adding support for MSI-X interrupts

From: David Miller <davem@davemloft.net>
Date: 2018-02-28 19:46:58

From: Heiner Kallweit <hkallweit1@gmail.com>
Date: Wed, 28 Feb 2018 20:43:38 +0100
In case of MSI-X the interrupt number may differ from pcidev->irq.
Fix this by using pci_irq_vector().

Fixes: 6c6aa15fdea5 ("r8169: improve interrupt handling")
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Applied, thank you.