Thread (5 messages) 5 messages, 2 authors, 2017-12-06

Re: [PATCH 2/2] veth: allow configuring GSO maximums

flat view

From: Solio Sarabia <hidden>
Date: 2017-12-06 01:50:42

On Tue, Dec 05, 2017 at 05:25:10PM -0800, Stephen Hemminger wrote:
On Tue,  5 Dec 2017 17:14:26 -0800
Solio Sarabia [off-list ref] wrote:
quoted
From: Stephen Hemminger <stephen@networkplumber.org>

Veth's can be used in environments (like Azure) where the underlying
network device is impacted by large GSO packets. This patch allows
gso maximum values to be passed in when creating the device via
netlink.

In theory, other pseudo devices could also use netlink attributes
to set GSO maximums but for now veth is what has been observed
to be an issue.

Signed-off-by: Stephen Hemminger <redacted>
Signed-off-by: Solio Sarabia <redacted>
I am testing new version with changelink support
Ack, I second whatever version works best.
Will help to try newer patches.