Thread (2 messages) flat view 2 messages, 2 authors, 2016-08-19

Re: [PATCH net-next] sfc: avoid division by zero

From: David Miller <davem@davemloft.net>
Date: 2016-08-19 06:28:38

From: Edward Cree <redacted>
Date: Wed, 17 Aug 2016 16:00:10 +0100
The division is already being done properly in efx_ef10_get_timer_config
which returns zero-on-success, unlike the old efx_ef10_get_sysclk_freq.

Fixes: d95e329a55ba ("sfc: get timer configuration from adapter")
Signed-off-by: Edward Cree <redacted>
Applied.