Thread (4 messages) flat view 4 messages, 3 authors, 2016-06-06

Re: [PATCH net] bnx2x: allow adding VLANs while interface is down

From: David Miller <davem@davemloft.net>
Date: 2016-06-06 03:12:14

From: Michal Schmidt <redacted>
Date: Fri,  3 Jun 2016 15:32:18 +0200
Since implementing VLAN filtering in commit 05cc5a39ddb74
("bnx2x: add vlan filtering offload") bnx2x refuses to add a VLAN while
the interface is down:

  # ip link add link enp3s0f0 enp3s0f0_10 type vlan id 10
  RTNETLINK answers: Bad address

and in dmesg (with bnx2x.debug=0x20):
  bnx2x: [bnx2x_vlan_rx_add_vid:12941(enp3s0f0)]Ignoring VLAN
  configuration the interface is down

Other drivers have no problem with this.
Fix this peculiar behavior in the following way:
 - Accept requests to add/kill VID regardless of the device state.
   Maintain the requested list of VIDs in the bp->vlan_reg list.
 - If the device is up, try to configure the VID list into the hardware.
   If we run out of VLAN credits or encounter a failure configuring an
   entry, fall back to accepting all VLANs.
   If we successfully configure all entries from the list, turn the
   fallback off.
 - Use the same code for reconfiguring VLANs during NIC load.

Signed-off-by: Michal Schmidt <redacted>
Applied, thanks.
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help