Thread (5 messages) flat view 5 messages, 3 authors, 2016-03-07

Re: [patch net 2/2] mlxsw: pci: Correctly determine if descriptor queue is full

From: Ido Schimmel <hidden>
Date: 2016-03-07 14:29:42

Mon, Mar 07, 2016 at 04:04:59PM IST, sergei.shtylyov@cogentembedded.com wrote:
Hello.

On 3/7/2016 11:24 AM, Jiri Pirko wrote:
quoted
From: Ido Schimmel <redacted>

The descriptor queues for sending (SDQs) and receiving (RDQs) packets
are managed by two counters - producer and consumer - which are both
16-bit in size. A queue is considered full when the difference between
the two equals the queue's maximum number of descriptors.

However, if the producer counter overflows, then it's possible for the
full queue check to fail, as it doesn't take the overflow into account.
In such a case, descriptors already passed to the device - but for which
a completion has yet to be posted - will be overwritten, thereby causing
undefined behavior. The above can be achieved under heavy load (~30
netperf instances).

Fix that by casting the substraction result to u16, preventing it from
   Subtraction.
Will fix that in v2.

Thanks!
quoted
being treated as a signed integer.

Fixes: eda6500a987a ("mlxsw: Add PCI bus implementation")
Signed-off-by: Ido Schimmel <redacted>
Signed-off-by: Jiri Pirko <redacted>
[...]

MBR, Sergei