Re: [patch net-next v2 01/28] net: dev: Check CHANGEUPPER notifier return value

From
John Fastabend <john.fastabend@gmail.com>
Date
2015-12-02 23:21:13
Reply to
Jiri Pirko, 2015-12-02
On 15-12-02 12:07 PM, Jiri Pirko wrote:
quoted hunk ↗ jump to hunk
From: Ido Schimmel <redacted>

switchdev drivers reflect the newly requested topology to hardware when
CHANGEUPPER is received, after software links were already formed.
However, the operation can fail and user will not be notified, as the
return value of the notifier is not checked.

Add this check and rollback software links if necessary.

Signed-off-by: Ido Schimmel <redacted>
Signed-off-by: Jiri Pirko <redacted>
---
v1->v2:
-new patch
---
 net/core/dev.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)
diff --git a/net/core/dev.c b/net/core/dev.c
index 5df6cbc..df33f82 100644
--- a/net/core/dev.c
+++ b/net/core/dev.c
@@ -5490,8 +5490,11 @@ static int __netdev_upper_dev_link(struct net_device *dev,
 			goto rollback_lower_mesh;
 	}
 
-	call_netdevice_notifiers_info(NETDEV_CHANGEUPPER, dev,
-				      &changeupper_info.info);
+	ret = call_netdevice_notifiers_info(NETDEV_CHANGEUPPER, dev,
+					    &changeupper_info.info);
+	if (ret)
+		goto rollback_lower_mesh;
+
hmm small nit (take it or leave it) but I think it would be more
correct if this was

	if (ret == NOTIFY_BAD)
		goto rollback_lower_mesh;

It seems that NOTIFY_DONE, NOTIFY_OK and NOTIFY_STOP_MASK would be
valid return codes that don't indicate an error. However seeing I
couldn't find any cases of NOTIFY_OK/NOTIFY_STOP_MASK from the
CHANGEUPPER event it doesn't matter in practice.

Thanks,
John
 	return 0;
 
 rollback_lower_mesh:
Thread (38 messages) 38 messages, 6 authors, last reply 2015-12-03
Keyboard shortcuts
hback out one level
jnext message in thread / next series-diff position
kprevious message in thread / previous series-diff position
ldrill in
Escclose help / fold thread tree
?toggle this help