Thread (5 messages) 5 messages, 2 authors, 2015-07-09

Re: [PATCH 2/2] mvneta: use inband status only when link type is "auto"

flat view

From: Florian Fainelli <f.fainelli@gmail.com>
Date: 2015-07-09 21:16:06
Also in: lkml, stable

On 09/07/15 13:26, Stas Sergeev wrote:
09.07.2015 21:18, Florian Fainelli пишет:
quoted
On 09/07/15 10:41, Stas Sergeev wrote:
quoted
The commit 898b2970e2c9 ("mvneta: implement SGMII-based in-band link
state
signaling") implemented the link parameters auto-negotiation
unconditionally.
Unfortunately it appears that some HW that implements SGMII protocol,
doesn't generate the inband status, so it is not possible to
auto-negotiate
anything with such HW.
What is the purpose of using the in-band status in the first place if
you end-up having to specify a 'fixed-link' property which contains most
of the link parameters: speed, duplex etc...?
You don't have to.
My config from today is as simple as:

fixed-link {
  link = "auto";
};

and that's all.
Without my today's patch, only 'speed' is a mandatory - not too much.
That makes me think that 'fixed-link' is not exactly what you want then,
you would probably want something like "marvell,use-in-band-status" or
something like this. It could be a more generic property that is not
Marvell specific after all, that would be fine.
-- 
Florian
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree