Thread (20 messages) 20 messages, 5 authors, 2015-02-25

Re: [PATCH v2 1/3] Ethernet packet sniffer: Device tree binding and vendor prefix

flat view

From: Mark Rutland <mark.rutland@arm.com>
Date: 2015-02-17 17:30:40
Also in: linux-devicetree, lkml

On Tue, Feb 17, 2015 at 05:13:19PM +0000, Stathis Voukelatos wrote:
Hi Mark,

On 17/02/15 16:35, Mark Rutland wrote:
quoted
quoted
quoted
quoted
+- tstamp-hz : frequency of the timestamp counter
Is this the frequency the clock is running at, or a frequency that it
should be programmed to in order to be used?

The former can be queried from the common clock framework, and if you
intended the latter the wording shuold be a little more explicit about
that being the case.
It is the frequency of the timestamp values supplied to the sniffer
module. It is used by the driver to convert to nanoseconds.
I was trying to be somewhat generic here and not assume that it
is necessarily the same as the 'tstamp' clock below, in which case we
could indeed obtain it using the common clock framework.
In what cases would it _not_ be the same? From your description this is
that clock, no?
quoted
quoted
See: include/linux/clocksource.h
The driver uses a cyclecounter and timecounter to convert raw timestamps
to nanoseconds. 'tstamp-shift' refers to the 'shift' field of the
cyclecounter structure, that can be used to improve the precision of
the conversion
Sure, but the very concept of a cyclecounter is a Linux implementation
detail. If we have the frequency of the timer we should be able to
dynamically generate this, so there's no need for this to be in the DT.
Most networking driver use hard-coded values for that, but in my case
I did not want to assume a certain fixed clock frequency. I will remove
it from the DT and generate it dynamically. There is a kernel function
clocks_calc_mult_shift() to do it but unfortunately it is not exported,
so I guess I will need to replicate the code.
Or submit a patch exporting it, along with the rationale for doing so?
quoted
quoted
quoted
As mentioned previously, I think the relation between this unit and the
MAC and/or PHY needs to be explicitly described in the DT.
Do you suggest a field along the lines of:
mac = <&eth_controller_0>;
The driver could check that it exists and is valid but does
not need to make use of it.
I would expect some level of the software stack to make use of it, or
you have no idea which ethernet interface is related to this monitoring
interface. Perhaps current systems only have one interface, but that
shouldn't be relied upon.
Yes, but the sniffer module is hard-wired to a certain Ethernet Mii
interface. We can add an entry to tie it to an Ethernet controller, but
apart of a sanity check I am not sure what else the S/W can do.
Fundamentally, the use-case for this is monitoring an ethernet
interface. So regardless of which kernel framework this plumbs into,
there needs to be a way to go from ethN to whatever this is exposed as.

Exposing a completely separate interface makes no sense. Singleton stuff
like that inevitably gets broken as someone later builds a board with
multiple instances of some similar IP block.

So I would imagine that either the link between interface and monitoring
interface would be described somewhere in the filesystem, or there'd be
a syscall/ioctl/whatever to go from an interface to the appropriate
monitoring interface.

That all depends on exactly how this gets exposed in the end, however.

Thanks,
Mark.
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help