Thread (16 messages) 16 messages, 4 authors, 2013-12-03

Re: [net v2 2/7] e1000: prevent oops when adapter is being closed and reset simultaneously

From: yzhu1 <hidden>
Date: 2013-12-02 09:50:13

On 12/01/2013 12:37 AM, Sergei Shtylyov wrote:
Hello.

On 30-11-2013 13:20, Jeff Kirsher wrote:
quoted
From: yzhu1 <redacted>
quoted
This change is based on a similar change made to e1000e support in
commit bb9e44d0d0f4 ("e1000e: prevent oops when adapter is being closed
and reset simultaneously").  The same issue has also been observed
on the older e1000 cards.
quoted
Here, we have increased the RESET_COUNT value to 50 because there are 
too
many accesses to e1000 nic on stress tests to e1000 nic, it is not 
enough
to set RESET_COUT 25. Experimentation has shown that it is enough to set
RESET_COUNT 50.
quoted
Signed-off-by: yzhu1 <redacted>
   Jeff, why are you accepting patches without real name in the 
sign-off line?
quoted
Tested-by: Aaron Brown <redacted>
Signed-off-by: Jeff Kirsher <redacted>
WBR, Sergei
Hi,

Thanks for the advice from Sergei. I made a new patch with the name 
"yanjun.zhu".

Best Regards!
Zhu Yanjun